ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 新潟医療福祉大学
  2. 学術雑誌論文
  3. Niigata journal of health and welfare
  4. Volume18 Number1 (2018)

A new method of hip joint moment’s evaluation

https://nsg.repo.nii.ac.jp/records/4714
https://nsg.repo.nii.ac.jp/records/4714
b2f2dd5e-1959-48ae-a091-27aeb84f31e0
名前 / ファイル ライセンス アクション
001_009_e1801.pdf 001_009_e1801.pdf (629.7 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-12-24
タイトル
タイトル A new method of hip joint moment’s evaluation
言語
言語 eng
キーワード
主題Scheme Other
主題 hip joint moments
キーワード
主題Scheme Other
主題 motion analysis
キーワード
主題Scheme Other
主題 mechanical work
キーワード
主題Scheme Other
主題 potential energy
キーワード
主題Scheme Other
主題 hip joint centre
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Aduayom-Ahego, Akouetevi

× Aduayom-Ahego, Akouetevi

Aduayom-Ahego, Akouetevi

Search repository
Ehara, Yoshihiro

× Ehara, Yoshihiro

Ehara, Yoshihiro

Search repository
Shimotori, Daiki

× Shimotori, Daiki

Shimotori, Daiki

Search repository
Inoue, Shota

× Inoue, Shota

Inoue, Shota

Search repository
抄録
内容記述タイプ Abstract
内容記述 Joint moments play very important role in biomechanical research related to lower limbs. Three–dimensional motion analysis is widely used in clinical decision making and sport biomechanics. The accuracy of joint moments is particularly important for data analysis. If the joint moments are not accurate, it will mislead the clinical judgment. However there is no method to verify the accuracy of joint moments. To assess the reliability of the joint moments, a new method should be developed. So a new method based on the principle of the transfer between mechanical lower limb work and potential energy was developed. Five healthy student volunteers participated in the study. The motion data were collected and were processed using VICON motion analysis system. The lower limb work and the potential energy were calculated and compared in four kinds of hip joint centre location estimation models. Using the new concept, one of the four models showed the least difference between the potential energy increase and mechanical work. With this concept, the model in which the most accurate joint moment can be calculated was identified. However, given that these techniques are commonly used in the motion analysis laboratory set by researchers and clinicians, more investigations are needed in order to upgrade laboratory setting and joint center prediction methods.
書誌情報 Niigata journal of health and welfare

巻 18, 号 1, p. 1-9, 発行日 2018
出版者
出版者 Niigata Society of Health and Welfare
ISSN
収録物識別子タイプ ISSN
収録物識別子 1346-8782
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11614542
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
フォーマット
内容記述タイプ Other
内容記述 application/pdf
資源タイプ
内容記述タイプ Other
内容記述 論文(Article)
資源タイプ・NII
Journal Article
資源タイプ・DCMI
text
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:06:58.503961
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3