WEKO3
アイテム
{"_buckets": {"deposit": "08172778-025e-46df-aa5e-33476406e078"}, "_deposit": {"created_by": 1, "id": "3540", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "3540"}, "status": "published"}, "_oai": {"id": "oai:nsg.repo.nii.ac.jp:00003540", "sets": ["94"]}, "author_link": ["13207", "13200", "13199", "13201", "13202", "13203", "13205", "13197", "13208", "13204", "13206", "13198"], "item_19_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "21", "bibliographicPageStart": "14", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "新潟医療福祉学会誌"}]}]}, "item_19_description_16": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_19_description_45": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_19_description_6": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "本研究の目的は、「装具なし」、「プラスチック製短下肢装具」(以下、P-AFO)、「摩擦制動継手付短下肢装具 (ドリームブレース : Dream Plastic Ankle Foot Orthoses)」(以下、DP-AFO) 装着の3条件で、装具装着側下肢の力学的および筋電図学的解析を行うことである。インフォームド・コンセントの得られた健常成人を対象に、一側下肢の足部に装具を装着し、平地歩行および階段降り動作を行った。使用機器は、三次元動作解析装置および床反力計を使用し、装具装着側下肢の関節角度、関節モーメントの測定および筋電図の記録を行った。解析は、装具装着側下肢が床面および階段面に接地している区間を3条件で比較検討した。その結果、ドリームブレースは、正常歩行に近似した関節角度、関節モーメントおよび筋活動を再現していることが明らかになった。\n", "subitem_description_type": "Abstract"}, {"subitem_description": "The purpose of this study was to investigate a kinetic and electromyogram analysis of the Dream Plastic Ankle Foot Orthoses (DP-AFO) while walking and descending staircases. One healthy adult participated in this study. DP-AFO was attached to one of the legs of the subject, assuming that the limb was affected. The movement was measured with 3D motion analysis system (VICON 512) and force plates (AMTI). We compared the state of the limb, when the foot was touching the floor or the stair. As a result, it was clarified that the DP-AFO reproduces the joint angle, the joint moment, and the EMG activities of normal walking.", "subitem_description_type": "Abstract"}]}, "item_19_publisher_35": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟医療福祉学会"}]}, "item_19_rights_14": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "本文データは国立情報学研究所により電子化されたものである"}]}, "item_19_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11614531", "subitem_source_identifier_type": "NCID"}]}, "item_19_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1346-8774", "subitem_source_identifier_type": "ISSN"}]}, "item_19_text_1": {"attribute_name": "Title in Japanese", "attribute_value_mlt": [{"subitem_text_value": "摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討"}]}, "item_19_text_17": {"attribute_name": "形態", "attribute_value_mlt": [{"subitem_text_value": "1367134 bytes"}]}, "item_19_text_2": {"attribute_name": "タイトル(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Study of Kinetic and Electromyography of Dream Plastic Ankle Foot Orthoses while Walking and Stair Descending"}]}, "item_19_text_46": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "Journal Article"}]}, "item_19_text_47": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Journal Article"}]}, "item_19_text_48": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_19_text_49": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "05"}]}, "item_19_text_78": {"attribute_name": "コメント", "attribute_value_mlt": [{"subitem_text_value": "新潟医療福祉大学"}]}, "item_19_version_type_18": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "相馬, 俊雄"}], "nameIdentifiers": [{"nameIdentifier": "13197", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大西, 秀明"}], "nameIdentifiers": [{"nameIdentifier": "13198", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "牧田, 光代"}], "nameIdentifiers": [{"nameIdentifier": "13199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 成登志"}], "nameIdentifiers": [{"nameIdentifier": "13200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "黒川, 幸雄"}], "nameIdentifiers": [{"nameIdentifier": "13201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "眞鍋, 敏朗"}], "nameIdentifiers": [{"nameIdentifier": "13202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Soma, Toshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Onishi, Hideaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13204", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Makita, Mitsuyo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13205", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Naritoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kurokawa, Yukio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Manabe, Toshiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "13208", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-10-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00004183519.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1400000.0, "url": {"label": "KJ00004183519.pdf", "url": "https://nsg.repo.nii.ac.jp/record/3540/files/KJ00004183519.pdf"}, "version_id": "8fc1d389-dd66-424a-ab60-845968f7857e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "摩擦制動継手付短下肢装具 (ドリームブレース)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "筋電図", "subitem_subject_scheme": "Other"}, {"subitem_subject": "関節モーメント", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Dream Plastic Ankle Foot Orthoses", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electromyography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "joint moment", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討"}, {"subitem_title": "Study of Kinetic and Electromyography of Dream Plastic Ankle Foot Orthoses while Walking and Stair Descending", "subitem_title_language": "en"}]}, "item_type_id": "19", "owner": "1", "path": ["94"], "permalink_uri": "https://nsg.repo.nii.ac.jp/records/3540", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-03-05"}, "publish_date": "2010-03-05", "publish_status": "0", "recid": "3540", "relation": {}, "relation_version_is_last": true, "title": ["摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討"], "weko_shared_id": 1}
摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討
https://nsg.repo.nii.ac.jp/records/3540
https://nsg.repo.nii.ac.jp/records/354071513969-be0b-4fb0-aa2a-8a1b4a4cccd0
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00004183519.pdf (1.4 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-03-05 | |||||
タイトル | ||||||
タイトル | 摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Study of Kinetic and Electromyography of Dream Plastic Ankle Foot Orthoses while Walking and Stair Descending | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 摩擦制動継手付短下肢装具 (ドリームブレース) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 筋電図 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 関節モーメント | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Dream Plastic Ankle Foot Orthoses | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | electromyography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | joint moment | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
Title in Japanese | ||||||
摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討 | ||||||
タイトル(英) | ||||||
en | ||||||
Study of Kinetic and Electromyography of Dream Plastic Ankle Foot Orthoses while Walking and Stair Descending | ||||||
著者 |
相馬, 俊雄
× 相馬, 俊雄× 大西, 秀明× 牧田, 光代× 佐藤, 成登志× 黒川, 幸雄× 眞鍋, 敏朗× Soma, Toshio× Onishi, Hideaki× Makita, Mitsuyo× Sato, Naritoshi× Kurokawa, Yukio× Manabe, Toshiro |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 本研究の目的は、「装具なし」、「プラスチック製短下肢装具」(以下、P-AFO)、「摩擦制動継手付短下肢装具 (ドリームブレース : Dream Plastic Ankle Foot Orthoses)」(以下、DP-AFO) 装着の3条件で、装具装着側下肢の力学的および筋電図学的解析を行うことである。インフォームド・コンセントの得られた健常成人を対象に、一側下肢の足部に装具を装着し、平地歩行および階段降り動作を行った。使用機器は、三次元動作解析装置および床反力計を使用し、装具装着側下肢の関節角度、関節モーメントの測定および筋電図の記録を行った。解析は、装具装着側下肢が床面および階段面に接地している区間を3条件で比較検討した。その結果、ドリームブレースは、正常歩行に近似した関節角度、関節モーメントおよび筋活動を再現していることが明らかになった。 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to investigate a kinetic and electromyogram analysis of the Dream Plastic Ankle Foot Orthoses (DP-AFO) while walking and descending staircases. One healthy adult participated in this study. DP-AFO was attached to one of the legs of the subject, assuming that the limb was affected. The movement was measured with 3D motion analysis system (VICON 512) and force plates (AMTI). We compared the state of the limb, when the foot was touching the floor or the stair. As a result, it was clarified that the DP-AFO reproduces the joint angle, the joint moment, and the EMG activities of normal walking. | |||||
書誌情報 |
新潟医療福祉学会誌 巻 4, 号 1, p. 14-21, 発行日 2004-11 |
|||||
出版者 | ||||||
出版者 | 新潟医療福祉学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1346-8774 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11614531 | |||||
権利 | ||||||
権利情報 | 本文データは国立情報学研究所により電子化されたものである | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | 論文(Article) | |||||
資源タイプ・NII | ||||||
Journal Article | ||||||
資源タイプ・DCMI | ||||||
text |