{"created":"2023-05-15T11:33:07.215215+00:00","id":3540,"links":{},"metadata":{"_buckets":{"deposit":"08172778-025e-46df-aa5e-33476406e078"},"_deposit":{"created_by":1,"id":"3540","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"3540"},"status":"published"},"_oai":{"id":"oai:nsg.repo.nii.ac.jp:00003540","sets":["6:10:11:94"]},"author_link":["13207","13200","13199","13201","13202","13203","13205","13197","13208","13204","13206","13198"],"item_19_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"21","bibliographicPageStart":"14","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"新潟医療福祉学会誌"}]}]},"item_19_description_16":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_19_description_45":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_19_description_6":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究の目的は、「装具なし」、「プラスチック製短下肢装具」(以下、P-AFO)、「摩擦制動継手付短下肢装具 (ドリームブレース : Dream Plastic Ankle Foot Orthoses)」(以下、DP-AFO) 装着の3条件で、装具装着側下肢の力学的および筋電図学的解析を行うことである。インフォームド・コンセントの得られた健常成人を対象に、一側下肢の足部に装具を装着し、平地歩行および階段降り動作を行った。使用機器は、三次元動作解析装置および床反力計を使用し、装具装着側下肢の関節角度、関節モーメントの測定および筋電図の記録を行った。解析は、装具装着側下肢が床面および階段面に接地している区間を3条件で比較検討した。その結果、ドリームブレースは、正常歩行に近似した関節角度、関節モーメントおよび筋活動を再現していることが明らかになった。\n","subitem_description_type":"Abstract"},{"subitem_description":"The purpose of this study was to investigate a kinetic and electromyogram analysis of the Dream Plastic Ankle Foot Orthoses (DP-AFO) while walking and descending staircases. One healthy adult participated in this study. DP-AFO was attached to one of the legs of the subject, assuming that the limb was affected. The movement was measured with 3D motion analysis system (VICON 512) and force plates (AMTI). We compared the state of the limb, when the foot was touching the floor or the stair. As a result, it was clarified that the DP-AFO reproduces the joint angle, the joint moment, and the EMG activities of normal walking.","subitem_description_type":"Abstract"}]},"item_19_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟医療福祉学会"}]},"item_19_rights_14":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"本文データは国立情報学研究所により電子化されたものである"}]},"item_19_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11614531","subitem_source_identifier_type":"NCID"}]},"item_19_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-8774","subitem_source_identifier_type":"ISSN"}]},"item_19_text_1":{"attribute_name":"Title in Japanese","attribute_value_mlt":[{"subitem_text_value":"摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討"}]},"item_19_text_2":{"attribute_name":"タイトル(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Study of Kinetic and Electromyography of Dream Plastic Ankle Foot Orthoses while Walking and Stair Descending"}]},"item_19_text_47":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Journal Article"}]},"item_19_text_48":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_19_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"相馬, 俊雄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大西, 秀明"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"牧田, 光代"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 成登志"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"黒川, 幸雄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"眞鍋, 敏朗"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Soma, Toshio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Onishi, Hideaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Makita, Mitsuyo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sato, Naritoshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kurokawa, Yukio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Manabe, Toshiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-10-30"}],"displaytype":"detail","filename":"KJ00004183519.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00004183519.pdf","url":"https://nsg.repo.nii.ac.jp/record/3540/files/KJ00004183519.pdf"},"version_id":"8fc1d389-dd66-424a-ab60-845968f7857e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"摩擦制動継手付短下肢装具 (ドリームブレース)","subitem_subject_scheme":"Other"},{"subitem_subject":"筋電図","subitem_subject_scheme":"Other"},{"subitem_subject":"関節モーメント","subitem_subject_scheme":"Other"},{"subitem_subject":"Dream Plastic Ankle Foot Orthoses","subitem_subject_scheme":"Other"},{"subitem_subject":"electromyography","subitem_subject_scheme":"Other"},{"subitem_subject":"joint moment","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討"},{"subitem_title":"Study of Kinetic and Electromyography of Dream Plastic Ankle Foot Orthoses while Walking and Stair Descending","subitem_title_language":"en"}]},"item_type_id":"19","owner":"1","path":["94"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-03-05"},"publish_date":"2010-03-05","publish_status":"0","recid":"3540","relation_version_is_last":true,"title":["摩擦制動継手付短下肢装具 (ドリームブレース) 装着時の歩行および階段降り時における力学的解析および筋電図学的検討"],"weko_creator_id":"1","weko_shared_id":1},"updated":"2023-05-15T12:11:43.352293+00:00"}