{"created":"2023-05-15T11:33:42.194277+00:00","id":4215,"links":{},"metadata":{"_buckets":{"deposit":"bf75be23-6240-42fa-bcf3-f3903b8c438b"},"_deposit":{"created_by":1,"id":"4215","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"4215"},"status":"published"},"_oai":{"id":"oai:nsg.repo.nii.ac.jp:00004215","sets":["6:10:11:65"]},"author_link":["16113","16114","16112","16111","16109","16110","16107","16108"],"item_19_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"14","bibliographicPageStart":"8","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"新潟医療福祉学会誌"}]}]},"item_19_description_16":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_19_description_45":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_19_description_6":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to evaluate reliability and validity of the newly developed external device to measure the knee rotation. Twenty healthy male subjects were examined and passive rotation of the knee was measured by “RotorMeter”. Internal and external rotation was measured applying 8Nm torque by two testers. Statistical analysis was performed by using the intra-class correlation coefficients( ICC) and the Bland-Altman analysis. Internal rotation was 50.4 and 50.6 degrees, external rotation was 53.3 and 51.2 degrees and total (internal + external) rotation was 103.6 and 101.8 degrees. ICC(1,1) for total rotation was 0.904 and 0.939 and ICC(2,2) for total rotation was 0.968. Systematic error of this measurement was not found.\n","subitem_description_type":"Abstract"},{"subitem_description":"膝関節の弛緩性は膝前十字靱帯損傷の内的危険因子とされ、前額面および矢状面内での弛緩性については多くの研究がなされてきた。しかし、水平面内での弛緩性、すなわち回旋方向の弛緩性と前十字靱帯損傷との関連については、膝関節の回旋量の定量化に関する方法論的課題から十分な検討がなされていない。そこで本研究は、新たに開発した回転円盤形角度測定器“RotorMeter”による、膝関節の回旋可動域の測定方法の信頼性と妥当性を検討することを目的とした。12名の健常男性を対象とし、2名の検者による各2回の測定が行われた。負荷トルクは8Nmとした。測定方法の信頼性の検討には級内相関係数が、妥当性の検討にはBland-Altman分析が用いられた。両検者の測定結果の平均値は、内旋可動域は50.4度および50.6度、外旋可動域は53.3度および51.2度、両可動域の和である全回旋可動域は103.6度および101.8度であった。検者内での級内相関係数は08.01から09.39、検者間での級内相関係数は09.17から09.68であり、測定結果の検者内および検者間の信頼性は良好と判定された。また、両検者内での測定結果の系統誤差は見られなかった。以上の結果より、RotorMeterを用いた膝関節の回旋方向可動域の測定方法は信頼性および妥当性のあるものと判定されたが、先行研究との比較から足関節および足部の諸関節の運動が測定結果に介在したものと考えられた。","subitem_description_type":"Abstract"}]},"item_19_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟医療福祉学会"}]},"item_19_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11614531","subitem_source_identifier_type":"NCID"}]},"item_19_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-8774","subitem_source_identifier_type":"ISSN"}]},"item_19_text_1":{"attribute_name":"Title in Japanese","attribute_value_mlt":[{"subitem_text_value":"回転円盤型角度測定器“RotorMeter”を用いた膝関節の回旋可動域の測定方法の信頼性と妥当性の検討"}]},"item_19_text_2":{"attribute_name":"タイトル(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Evaluation of Reliability and Validity of An External Device to Measure The Knee Rotation"}]},"item_19_text_47":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Journal Article"}]},"item_19_text_48":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_19_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"柵木, 聖也"}],"nameIdentifiers":[{"nameIdentifier":"16107","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石倉, 孝樹"}],"nameIdentifiers":[{"nameIdentifier":"16108","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石関, 友也"}],"nameIdentifiers":[{"nameIdentifier":"16109","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮川, 俊平"}],"nameIdentifiers":[{"nameIdentifier":"16110","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masegi, Seiya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16111","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishikura, Kouki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16112","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishizeki, Tomoya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16113","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Miyakawa, Shunpei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"16114","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-10-30"}],"displaytype":"detail","filename":"008_014_w1302.pdf","filesize":[{"value":"2.7 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"008_014_w1302.pdf","url":"https://nsg.repo.nii.ac.jp/record/4215/files/008_014_w1302.pdf"},"version_id":"b5a15059-87b7-4135-aeea-42ab65cfc284"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"膝関節","subitem_subject_scheme":"Other"},{"subitem_subject":"測定方法","subitem_subject_scheme":"Other"},{"subitem_subject":"回旋","subitem_subject_scheme":"Other"},{"subitem_subject":"弛緩性","subitem_subject_scheme":"Other"},{"subitem_subject":"RotorMeter","subitem_subject_scheme":"Other"},{"subitem_subject":"knee joint","subitem_subject_scheme":"Other"},{"subitem_subject":"measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"rotation","subitem_subject_scheme":"Other"},{"subitem_subject":"joint laxity","subitem_subject_scheme":"Other"},{"subitem_subject":"RotorMeter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"knee joint","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"rotation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"joint laxity","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"膝関節","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"測定方法","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"回旋","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"弛緩性","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"回転円盤型角度測定器“RotorMeter”を用いた膝関節の回旋可動域の測定方法の信頼性と妥当性の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"回転円盤型角度測定器“RotorMeter”を用いた膝関節の回旋可動域の測定方法の信頼性と妥当性の検討"},{"subitem_title":"Evaluation of Reliability and Validity of An External Device to Measure The Knee Rotation","subitem_title_language":"en"}]},"item_type_id":"19","owner":"1","path":["65"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-06-16"},"publish_date":"2014-06-16","publish_status":"0","recid":"4215","relation_version_is_last":true,"title":["回転円盤型角度測定器“RotorMeter”を用いた膝関節の回旋可動域の測定方法の信頼性と妥当性の検討"],"weko_creator_id":"1","weko_shared_id":1},"updated":"2023-05-15T12:01:17.532818+00:00"}